Product Description:

Qualtech Products Industry Laboratory Scale is an Electronic High Precision Analytical Scale for the professional and instant high-precision weighing of samples including solid samples, powders and liquids for research and quality management.

This professional Laboratory Analytical Scale offers the newest microchip technology combined with a comfortable to read large Color LCD Display, comfortable Softtouch Buttons, a convenient Glass Enclosure for increased weighing accuracy, High Accuracy and High Precision, Automatic Calibration, Instant Sample Measurement Mode, Automatic Sample Measurement, Unit Conversion including g, ct, ozt. lb and more, user-friendly Application, user-friendly Programming, user-friendly Sample Handling, integrated counter, Direct Printing, optional seamless PC-Connectivity and PC-Software, ergonomic design, reliable performance and much more.

This professional Laboratory Weighing Scale is a synergie of advanced sample measurement technology, user-friendly application and high accuracy for research and quality management.

This precision Laboratory Analytical Scale is designed and engineered in accordance with international test standards.

Professional Applications and Operation of the QPI-PS120 Laboratory Precision Balance:

Precision mass measurement serves as the foundation for modern scientific research, industrial quality control, and advanced material synthesis. Whether formulating complex chemical reagents, conducting gravimetric analysis, or performing precise sample preparation for spectroscopy, accurate weight data directly dictates the reliability of downstream experimental results.

The Qualtech Products Industry Laboratory Precision Balance (Model QPI-PS120) is engineered to meet the stringent demands of laboratory workflows, providing sub-milligram readability, fast response times, and robust operational stability. This guide explores the core technical architecture, essential applications, and best operational practices for utilizing the QPI-PS120 in professional laboratory and educational environments.

Technical Architecture & Performance Capabilities

The QPI-PS120 integrates high-performance microchip processing with a heavy-duty load cell assembly to deliver precise measurements under variable laboratory conditions. Key performance characteristics include:

  • High Readability (0.001 g / 1 mg): Enables precise determination of small sample masses, suitable for fine chemical dosing and micro-titration prep.

  • Maximum Capacity (120 g): Accommodates standard laboratory glassware, weighing boats, and crucible hardware alongside target samples.

  • Integrated Draft Shield: Eliminates local micro-drafts, thermal convection currents, and atmospheric disturbance during measurement.

  • RS232 Data Interface: Provides direct connectivity to external printers, computers, and Laboratory Information Management Systems (LIMS) for seamless data logging.

Primary Applications in Research and Industry

1. Gravimetric Analysis and Reagent Preparation

In analytical chemistry, gravimetric techniques require accurate mass measurement before and after chemical transformations (such as precipitation, evaporation, or combustion). The QPI-PS120 allows researchers to measure accurate initial precursor masses and determine precise yield percentages, minimizing compounding errors in stoichiometry calculations.

2. Textile and Material Density Testing

When paired with circular sample cutters (such as GSM cutters) or specific density determination kits, the QPI-PS120 measures the surface weight (g/m²) of textiles, paper, polymers, and foil samples. Precision down to 0.001 g is critical when evaluating thin-film coatings, non-woven fabrics, and high-performance technical textiles where slight variations indicate manufacturing flaws.

3. Quality Assurance (QA) and Quality Control (QC)

Industrial manufacturing facilities—ranging from pharmaceutical production to specialized rubber and plastic synthesis—rely on strict batch consistency. QC technicians use the QPI-PS120 to verify component ratios, measure sample moisture loss during drying cycles, and audit finished product tolerances against ASTM, ISO, and DIN standards.

4. Advanced Academic Instruction

For engineering and chemistry students, mastering high-precision laboratory balances builds core laboratory competence. The QPI-PS120 provides an intuitive interface with standard tactile function keys (Tare, Unit Conversion, Calibration), allowing students to focus on fundamental principles of measurement uncertainty, buoyancy corrections, and error analysis without navigating overly complex menu trees.

Step-by-Step Standard Operating Procedure (SOP)

To maintain measurement accuracy and extend instrument lifespan, operators should follow standard weighing protocols:

  1. Environmental Setup: Place the balance on a stable, vibration-free granite or heavy laboratory bench away from direct sunlight, HVAC vents, and magnetic interference. Level the unit using the adjustable leveling feet and the integrated bubble spirit level.

  2. Warm-Up Phase: Connect the unit to standard AC power and allow a 15- to 30-minute warm-up period to stabilize internal electronic components thermally.

  3. Draft Shield Management: Ensure all sliding glass doors are fully closed prior to zeroing or recording final readings.

  4. Zeroing and Taring: Place your clean weighing vessel (weighing paper or boat) onto the center of the stainless steel pan. Press the Tare key to zero out the container weight.

  5. Sample Loading: Carefully introduce the sample material into the vessel using a clean spatula. Avoid spilling reagents directly onto the pan or lower chamber housing.

  6. Reading Final Mass: Allow the digital display stabilization indicator to illuminate before recording the value or transferring data via the RS232 port.

Calibration and Routine Maintenance

Regular calibration ensures measurement traceability to national metrology standards. The QPI-PS120 supports automated calibration routines using external standard weights (e.g., F1 Class calibration masses).

  • Routine Daily Checks: Clean the weighing chamber with a soft brush or lint-free cloth. Remove any spilled particulates immediately to prevent corrosion or mechanical binding.

  • Periodic Calibration: Perform a full span calibration weekly or whenever the balance is relocated, subjected to significant ambient temperature shifts, or power-cycled.

  • Handling Standards: Always handle calibration weights using non-magnetic tweezers or cotton gloves to prevent oil transfer from hands, which can alter sub-milligram mass values.

By adhering to proper calibration schedules and environmental precautions, the QPI-PS120 delivers consistent, repeatable, and traceable measurement results across all academic and industrial testing workflows.

High Precision Weighing Scale – Features:

  • Newest Microchip Technology
  • Instant Professional Laboratory Weighing
  • Large LCD Display with Backlight
  • Comfortable Softtouch Buttons
  • High Resolution Display
  • Glass Enclosure
  • User-friendly Application
  • User-friendly Programming
  • User-friendly Sample Handling
  • Automatic Gross Weight to Net Weight Conversion
  • Unit Conversion including g, CT, OZ, lb and many more
  • LED Indicators
  • Automatic Calibration
  • Optional Seamless PC-Connectivity
  • High Accuracy & High Precision
  • Ergonomic Design & Reliable Performance
  • Robust Design & Longevity
  • Engineered in accordance with international test standards

Laboratory Weighing Scale – Specifications:

ModelMax Load CapacityResolutionPlatform SizeHurricane Globe
QPI-PS50110 g0.1 mgØ 80 mmOptional Accessory
QPI-PS60120 g0.1 mgØ 80 mmOptional Accessory
QPI-PS70160 g0.1 mgØ 80 mmOptional Accessory
QPI-PS80210 g0.1 mgØ 80 mmOptional Accessory
QPI-PS90220 g0.1 mgØ 80 mmOptional Accessory
QPI-PS100100 g0.001 gØ 80 mmOptional Accessory
QPI-PS110200 g0.001 gØ 80 mmOptional Accessory
QPI-PS120300 g0.001 gØ 80 mmOptional Accessory
QPI-PS130400 g0.001 gØ 80 mmOptional Accessory
QPI-PS140500 g0.001 gØ 80 mmOptional Accessory
QPI-PS150600 g0.001 gØ 80 mmOptional Accessory
QPI-PS1601000 g0.001 gØ 80 mmOptional Accessory
QPI-PS1701200 g0.001 gØ 80 mmOptional Accessory
QPI-PS125110 g0.01 gØ 125 mmOptional Accessory
QPI-PS135210 g0.01 gØ 125 mmOptional Accessory
QPI-PS145310 g0.01 gØ 125 mmOptional Accessory
QPI-PS155510 g0.01 gØ 125 mmOptional Accessory
QPI-PS165610 g0.01 gØ 125 mmOptional Accessory
QPI-PS10001,100 g0.01 gØ 125 mmOptional Accessory
QPI-PS11002,100 g0.01 gØ 125 mmOptional Accessory
QPI-PS1300S5,100 g0.01 gØ 180 mmOptional Accessory
QPI-PS13003,100 g0.1 g155 mm x 175 mmOptional Accessory
QPI-PS16008,000 g0.1 g160 mm x 180 mmOptional Accessory
High Accuracy & High PrecisionYesYesYesYes
Ergonomic Design & Reliable PerformanceYes
Voltage100VAC - 240VAC 50Hz/60Hz
Engineered in accordance with recognized international test standards

High Precision Laboratory Weighing Scale – Included items:

  • Automatic High Precision Laboratory Weighing Scale
  • Accessories
  • Calibration Weight
  • Power Adapter
  • Quality Certificate
  • Carefully Calibrated
  • Calibration Certificate
  • User manual
  • Extended Warranty

Get information now on products, pricing, technical support and professional services.