Wedi anghofio'ch manylion?

CYNHYRCHION QUALTECH DYFIANT

CYNHYRCHION QUALTECH DYFIANT

Offerynnau Profi Paent a Gorchuddion

Gwerthoedd Gwirioneddol i'n Cwsmeriaid a'n Cleientiaid

CYNHYRCHION QUALTECH DYFIANT

Offer Cynhyrchu Diwydiannol

Peiriannau ar raddfa ddiwydiannol ar gyfer llinellau cynhyrchu

Offer Dibynadwy ar gyfer Eich Cynhyrchion

CYNHYRCHION QUALTECH DYFIANT

Cemegau ar gyfer cynhyrchu paent

Pigmentau a Chlymwyr a Mwy

Cemegion i gefnogi eich cynhyrchion

CYNHYRCHION QUALTECH DYFIANT

Gwerthoedd Gwirioneddol i'n Cwsmeriaid a'n Cleientiaid

Ansawdd Dibynadwy

Gwasanaeth Proffesiynol

CYNHYRCHION QUALTECH DYFIANT

Ansawdd Dibynadwy

Uchel Dechnoleg

Gwasanaeth Proffesiynol

Blaenorol
nesaf

Cofrestrwch yma am y diweddaraf a newyddion

Disgrifiad o'r cynnyrch:

Diwydiant Cynhyrchion Qualtech Sgiliau Labordy yn Cloriannau a Bwysau Electronig o Uchel Gywirdeb yn cynnig y dechnoleg micro-sglodyn ddiweddaraf wedi'i chyfuno â Sgrin Gyffwrdd Lliw fawr, gyfforddus i'w darllen, Closyniad Gwydr cyfleus ar gyfer cywirdeb uwch, Uchel Gywirdeb ac Uchel Fanwl-gywirdeb, Calibro Awtomatig, Modd Mesur Samplau Ar Unwaith, Mesur Samplau Awtomatig, Trawsnewid Unedau gan gynnwys g, ct, ozt. lb a mwy, Ap defnyddiwr hawdd ei ddefnyddio, Rhaglennu hawdd ei ddefnyddio, Trin samplau hawdd ei ddefnyddio, cyfrifydd integredig, Argraffu uniongyrchol, cysylltedd a meddalwedd PC di-dor, dyluniad ergonomig, perfformiad dibynadwy a llawer mwy.

Y rhain broffesiynol Sgäl Labordy ac Cwmpawd Labordy Mae wedi'i beiriannu i gynnig technoleg mesur samplau ddatblygedig ynghyd â manwl gywirdeb uchel ar gyfer ymchwil a rheoli ansawdd.

Mae'r Clorianau a'r Balansau manwl gywir hyn wedi'u dylunio a'u peiriannu yn unol â safonau prawf rhyngwladol cydnabyddedig.

Professional Applications and Operation of the QPI-PS Series Laboratory Precision Balance:

Precision mass measurement serves as the foundation for modern scientific research, industrial quality control, and advanced material synthesis. Whether formulating complex chemical reagents, conducting gravimetric analysis, or performing precise sample preparation for spectroscopy, accurate weight data directly dictates the reliability of downstream experimental results.

Y Qualtech Products Industry Laboratory Precision Balance Model QPI-PS120 is engineered to meet the stringent demands of laboratory workflows, providing sub-milligram readability, fast response times, and robust operational stability. This guide explores the core technical architecture, essential applications, and best operational practices for utilizing the QPI-PS120 in professional laboratory and educational environments.

Technical Architecture & Performance Capabilities

The QPI-PS120 integrates high-performance microchip processing with a heavy-duty load cell assembly to deliver precise measurements under variable laboratory conditions. Key performance characteristics include:

  • High Readability (0.001 g / 1 mg): Enables precise determination of small sample masses, suitable for fine chemical dosing and micro-titration prep.

  • Maximum Capacity (120 g): Accommodates standard laboratory glassware, weighing boats, and crucible hardware alongside target samples.

  • Integrated Draft Shield: Eliminates local micro-drafts, thermal convection currents, and atmospheric disturbance during measurement.

  • RS232 Data Interface: Provides direct connectivity to external printers, computers, and Laboratory Information Management Systems (LIMS) for seamless data logging.

Primary Applications in Research and Industry

1. Gravimetric Analysis and Reagent Preparation

In analytical chemistry, gravimetric techniques require accurate mass measurement before and after chemical transformations (such as precipitation, evaporation, or combustion). The QPI-PS120 allows researchers to measure accurate initial precursor masses and determine precise yield percentages, minimizing compounding errors in stoichiometry calculations.

2. Textile and Material Density Testing

When paired with circular sample cutters (such as GSM cutters) or specific density determination kits, the QPI-PS120 measures the surface weight (g/m²) of textiles, paper, polymers, and foil samples. Precision down to 0.001 g is critical when evaluating thin-film coatings, non-woven fabrics, and high-performance technical textiles where slight variations indicate manufacturing flaws.

3. Quality Assurance (QA) and Quality Control (QC)

Industrial manufacturing facilities—ranging from pharmaceutical production to specialized rubber and plastic synthesis—rely on strict batch consistency. QC technicians use the QPI-PS120 to verify component ratios, measure sample moisture loss during drying cycles, and audit finished product tolerances against ASTM, ISO, and DIN standards.

4. Advanced Academic Instruction

For engineering and chemistry students, mastering high-precision laboratory balances builds core laboratory competence. The QPI-PS120 provides an intuitive interface with standard tactile function keys (Tare, Unit Conversion, Calibration), allowing students to focus on fundamental principles of measurement uncertainty, buoyancy corrections, and error analysis without navigating overly complex menu trees.

Step-by-Step Standard Operating Procedure (SOP)

To maintain measurement accuracy and extend instrument lifespan, operators should follow standard weighing protocols:

  1. Environmental Setup: Place the balance on a stable, vibration-free granite or heavy laboratory bench away from direct sunlight, HVAC vents, and magnetic interference. Level the unit using the adjustable leveling feet and the integrated bubble spirit level.

  2. Warm-Up Phase: Connect the unit to standard AC power and allow a 15- to 30-minute warm-up period to stabilize internal electronic components thermally.

  3. Draft Shield Management: Ensure all sliding glass doors are fully closed prior to zeroing or recording final readings.

  4. Zeroing and Taring: Place your clean weighing vessel (weighing paper or boat) onto the center of the stainless steel pan. Press the Tare key to zero out the container weight.

  5. Llwytho Sampl: Carefully introduce the sample material into the vessel using a clean spatula. Avoid spilling reagents directly onto the pan or lower chamber housing.

  6. Reading Final Mass: Allow the digital display stabilization indicator to illuminate before recording the value or transferring data via the RS232 port.

Calibration and Routine Maintenance

Regular calibration ensures measurement traceability to national metrology standards. The QPI-PS120 supports automated calibration routines using external standard weights (e.g., F1 Class calibration masses).

  • Routine Daily Checks: Clean the weighing chamber with a soft brush or lint-free cloth. Remove any spilled particulates immediately to prevent corrosion or mechanical binding.

  • Periodic Calibration: Perform a full span calibration weekly or whenever the balance is relocated, subjected to significant ambient temperature shifts, or power-cycled.

  • Handling Standards: Always handle calibration weights using non-magnetic tweezers or cotton gloves to prevent oil transfer from hands, which can alter sub-milligram mass values.

By adhering to proper calibration schedules and environmental precautions, the QPI-PS120 delivers consistent, repeatable, and traceable measurement results across all academic and industrial testing workflows.

Sgäl Pwyso Manwl Uchel gyda Sgrin Gyffwrdd Liw – Nodweddion:

  • Technoleg Micro-sglodyn ddiweddaraf
  • Pwyso Labordy Proffesiynol Ar Unwaith
  • Arddangosfa Sgrin Gyffwrdd Lliw Fawr gyda Chefn-oleuadau
  • Botymau Meddal Cyfforddus
  • Arddangosfa cydraniad uchel
  • Cais hawdd ei ddefnyddio
  • Rhaglennu hawdd ei ddefnyddio
  • Trin Samplau Hawdd ei Ddefnyddio
  • Trawsnewid Awtomatig o Bwysau Gros i Bwysau Net
  • Trawsnewid Unedau gan gynnwys g, CT, OZ, lb a llawer mwy
  • Arwyddion LED
  • Cloyfa wydr gyda drws uchaf a drws blaen
  • Calibru Awtomatig
  • Cysylltedd PC di-dor dewisol
  • Cywirdeb Uchel a Manwl-gywirdeb Uchel
  • Dyluniad Ergonomig a Pherfformiad Dibynadwy
  • Dyluniad Cadarn a Hirhoedledd
  • Peirianyddwyd yn unol â safonau profi rhyngwladol

Cwmpawd Labordy a Sgales Labordy gyda sgrin gyffwrdd lliw – Manylebau:

ModelCapasiti Llwyth UchafPenderfyniadMaint y PlatfformGlôb Corwynt
QPI-PS50TS110 g0.1 mgØ 80 mmAtegolyn dewisol
QPI-PS60TS120 g0.1 mgØ 80 mmAtegolyn dewisol
QPI-PS70TS160 g0.1 mgØ 80 mmAtegolyn dewisol
QPI-PS80TS210 g0.1 mgØ 80 mmAtegolyn dewisol
QPI-PS90TS220 g0.1 mgØ 80 mmAtegolyn dewisol
QPI-PS100TS100 g0.001gØ 80 mmAtegolyn dewisol
QPI-PS110ST200 g0.001gØ 80 mmAtegolyn dewisol
QPI-PS120TS300 g0.001gØ 80 mmAtegolyn dewisol
QPI-PS130TS400 g0.001gØ 80 mmAtegolyn dewisol
QPI-PS140TS500 g0.001gØ 80 mmAtegolyn dewisol
QPI-PS150TS600 g0.001gØ 80 mmAtegolyn dewisol
QPI-PS160TS1000 g0.001gØ 80 mmAtegolyn dewisol
QPI-PS170TS1200 g0.001gØ 80 mmAtegolyn dewisol
QPI-PS125TS110 g0.01 gØ 125 mmAtegolyn dewisol
QPI-PS135TS210 g0.01 gØ 125 mmAtegolyn dewisol
QPI-PS145TS310 g0.01 gØ 125 mmAtegolyn dewisol
QPI-PS155TS510 g0.01 gØ 125 mmAtegolyn dewisol
QPI-PS165TS610 g0.01 gØ 125 mmAtegolyn dewisol
QPI-PS1000TS1,100 g0.01 gØ 125 mmAtegolyn dewisol
QPI-PS1100TS2,100 g0.01 gØ 125 mmAtegolyn dewisol
QPI-PS1300STS5,100 g0.01 gØ 180 mmAtegolyn dewisol
QPI-PS1300TS3,100 g0.1 g155 mm x 175 mmAtegolyn dewisol
QPI-PS1600TS8,000 g0.1 g160 mm x 180 mmAtegolyn dewisol

Sgales Labordy Manwl-uchel gyda Sgrin Gyffwrdd Liw – Eitemau wedi'u cynnwys:

  • Clorian Awtomatig Manwl-Uchel
  • Ategolion
  • Pwysau graddnodi
  • Addasydd pŵer
  • Tystysgrif Ansawdd
  • Graddnodedig yn ofalus
  • Tystysgrif Graddnodi
  • Llawlyfr defnyddiwr
  • Gwarant estynedig

Cewch wybodaeth nawr am gynhyrchion, prisiau, cymorth technegol a gwasanaethau proffesiynol.
Bydd un o'n harbenigwyr yn ateb eich ymholiad cyn bo hir. Fel arall, cysylltwch â ni drwy fanylion y cwmni yn yr Unol Daleithiau, yn Awstralia neu yn y DU.

Gweler rai o'n cleientiaid gwerthfawr:

Offerynnau Profi Labordy
uchaf
gwall: